% run in voltage clamp mode varval_str=get(handles.vc_varval_box, 'String'); if (length(regexp(varval_str,'[^\.\s\d,\-]'))~=0) varval_str=regexprep(varval_str,'[^\.\s\d,\-]',''); set(handles.vc_varval_box, 'String', varval_str); end %to initialize vertical slider vars.vc_vertslider_set_var = 0; vars.vc_slider_set_var = 0; %valsarray holds numbers in vc_varval_box (vstim voltages) valsarray=str2num(varval_str); %iterates N number of times. N = # of voltage steps indicated for i=1:length(valsarray) vars.curve_aborted=0; vc_addcurve(valsarray(i)); if (vars.curve_aborted), break; end end