>>> 'spinner1' problem from marilyn -- Wed Jan 11 16:21:32 1989 <<<

Problem: No vacuum at all.

>>> 'spinner1' problem from hebert -- Thu Jan 12 08:02:00 1989 <<<

The spinner doesn't work.

>>> 'spinner1' problem from bob -- Thu Jan 12 10:19:31 1989 <<<

The solenoid on spinner1 was removed and cleaned. The loss of wafer sensor
was adjusted and is now operating. 
spinner1 is up for use.

>>> 'spinner1' problem from hebert -- Thu Jan 19 08:58:11 1989 <<<

The spinner doesn't rotate. The motor shaft doesn't turn even
by hand. The motor appears to be stuck.

>>> 'spinner1' problem from evan -- Thu Jan 19 11:01:37 1989 <<<

problem: no rotation
cause: photoresist build-up around the collar.
solution: removed chuck plate and cleaned around the collar with acetone.
          also flushed vacuum line.  Retightened collar, replaced plate
          and foil.
     
      USERS! Do not allow photoresist to get sucked into the vacuum system.
             If excess photoresist spills around the motor shaft, wipe it
             out when you replace the foil.

>>> 'spinner1' problem from evan -- Thu Jan 19 11:07:13 1989 <<<

I forgot to say:
The spinner is up and rotating.

>>> 'spinner1' problem from evan -- Mon Jan 30 10:46:02 1989 <<<

spinner1 is down
operator reported non operation on the canon account.
cause: vacuum detection solenoid is not activation motor microswitch.
I will be cleaning the vacuum lines.
spinner should be up this afternoon

>>> 'spinner1' problem from evan -- Mon Jan 30 11:56:12 1989 <<<

problem: no motor rotation
cause: THE VACUUM SYSTEM WAS PLUGGED WITH PHOTORESIST AGAIN!
solution: Complete disassembly of fittings and solenoid, clean
in ultrasonic, reassembled.  Put on a new vacuum line (the old
one was almost a solid plug.

USERS: Again, be careful not no get excess resist in the area around
the motor shaft.

The spinner is up.

>>> 'spinner1' problem from phillip -- Mon Jan 30 13:34:41 1989 <<<

test

>>> 'spinner1' problem from bob -- Tue Sep 19 15:06:29 1989 <<<

The knob on the spinner cover has worn off. A new one will be ordered.
In the meantime the spinner is useable with only minor inconvenience.

>>> 'spinner1' problem from phillip -- Wed Sep 27 07:28:59 1989 <<<

P: Splash guard installed up side down thus adding
   to the splashing.
S: Cleaned spinner. Foiled and installed splash
   guard correctly.


The knob for the case is still on order.

>>> 'spinner1' problem from evan -- Wed Nov  1 13:30:27 1989 <<<

Vapor removal ducts have been installed on the photo-resist baking
hot plates in Y1.

>>> 'spinner1' problem from hebert -- Fri Apr 13 10:01:40 1990 <<<

The lid lock has fallen apart. The inner lid won't stay in place.

>>> 'spinner1' fix from evan -- Fri Apr 13 15:37:21 1990 <<<

problem: lid won't lock
cause: lid warped
solution: bent the lid so it was flat. aligned the lock and lock pin.
spinner1 lid now locks