>>> 'aptchrome' problem from marilyn -- Wed Jan  3 16:09:26 1990 <<<

Problem: water doesn't drain out fast enough during rinse steps
         (use Program 99 to check out and observe)

>>> 'aptchrome' problem from phillip -- Thu Jan  4 06:33:40 1990 <<<

P: Drains slow per Marilyn.
S: Removed mushroom door slide from top
   of drain. Refastened slide to proper
   place with temp. screw.

This machine is up.

>>> 'aptchrome' problem from marilyn -- Wed Feb 21 15:43:45 1990 <<<

Problem: Programs 90-91-92 (develop-etch-strip) lost
Cause: Glitch
Solution: reprogrammed back in

>>> 'aptchrome' problem from marilyn -- Tue Feb 27 16:16:37 1990 <<<

Problem: APTchrome has been randomly loing programs; this has happened
         three times within the last  1 1/2 weeks.
Cause:   Bad board?
Solution: Each time a program or programs have been lost, they have
          been reprogrammed back in.  However, this is a temporary
          fix.  The aptchrome is able to be used as long as it is
          reprogrammed.

>>> 'aptchrome' problem from bob -- Wed Feb 28 13:39:20 1990 <<<

The loss of programs on the aptchrome may be caused by a bad
battery used for backup. Phillip is going to check this out
and replace both batteries, aptchrome & aptemul.

>>> 'aptchrome' problem from bob -- Wed Feb 28 15:56:56 1990 <<<

The aptchrome is down for the evening due to power problems with sink10.
sink10 is the drain for the aptchrome.

>>> 'aptchrome' problem from phillip -- Fri Mar  2 08:33:43 1990 <<<

The problem with power that involved this machine has been cleared.
This machine is up.

>>> 'aptchrome' problem from marilyn -- Wed Mar  7 14:42:47 1990 <<<

Problem: lamp on the wane
Solution: replaced lamp

>>> 'aptchrome' problem from marilyn -- Fri Mar  9 14:08:03 1990 <<<

Problem: All processing programs wiped out when battery was changed.
Solution: All programs reprogrammed back in; the APTchrome is up.

>>> 'aptchrome' problem from marilyn -- Mon Mar 12 13:44:25 1990 <<<

Problem: All programs wiped out when power was turned on.
Solution: Reprogrammed them back in: Programs 81, 90, 91, 92,
          93, 99.

>>> 'aptchrome' problem from phillip -- Tue Mar 13 14:09:27 1990 <<<

The chrome machine holds its programs with the power switch 'off'
as it should.,
No trouble found as to the source of the problem as reported by Marilyn.

>>> 'aptchrome' problem from marilyn -- Thu Mar 15 08:17:51 1990 <<<

Problem: all programs lost
Solution: reprogrammed back in (81,90.91,92,93,99)

>>> 'aptchrome' problem from marilyn -- Fri Mar 16 08:33:41 1990 <<<

Problem: All programs erased when power turned on.
Cause: Undetermined.
Solution: Reprogrammed.

>>> 'aptchrome' problem from bob -- Fri Mar 16 10:58:20 1990 <<<

The aptchrome is having trouble with storing recipes. New RAM has been
ordered which should solve this problem. Until the, recipes may have
to be periodically re-entered.

>>> 'aptchrome' problem from phillip -- Tue Mar 27 08:59:31 1990 <<<

The chrome machine is now 'memory stable' with the addition
of a new 3V lithium battery and 2 new memory chips.

>>> 'aptchrome' problem from phillip -- Tue Apr  3 11:04:38 1990 <<<

The parts for this machine are still on order.
They have been shipped from the factory but have
not arrived here yet.

>>> 'aptchrome' problem from marilyn -- Mon Apr  9 14:57:12 1990 <<<

Problem: Water supply to aptchrome suddenly lost.

>>> 'aptchrome' problem from marilyn -- Tue Apr 10 10:42:54 1990 <<<

Problem: Develop Program 90, step 1: 10 second water rinse fails to
         provide water.  The program has been erased twice and
         re-programmed back in with the same result. Checked with the
         group in GL4; they are not doing anything unusual.

>>> 'aptchrome' problem from marilyn -- Tue Apr 10 13:19:45 1990 <<<

New problem: new memory chips have failed.

>>> 'aptchrome' fix from marilyn -- Tue Apr 10 14:35:20 1990 <<<

Problem: For all programs, no water at water rinse steps
Solution: PG replaced a part for the water line

>>> 'aptchrome' fix from phillip -- Tue Apr 10 14:40:04 1990 <<<

P:D.I. water intermittently dispersed through
  the program.
S: Replaced defected d.i. h2o solenoid.
The problem as reported by Marilyn is fixed.
The aptchrome is up and available for use.

>>> 'aptchrome' problem from phillip -- Fri Apr 20 14:05:39 1990 <<<

P: Per a verbal report from Debbie;
`  The developer pump is OUT. Otto is removing it.
  The motor turns but the pump mechanism is apparently
 shot. Ordering a new one will be looked into.

>>> 'aptchrome' problem from debra -- Fri Apr 20 14:45:57 1990 <<<

Pump for Shipley Microposit Developer Concentrate is not working (see
Phill's report). This is the chemical used to do the final PR strip
after etching chrome mask. You can still use Prog. #90 (Develop),
#91 (Etch), #92 (to expose PR using lamp), however you must hand strip
the PR after #92. This can be accomplished by using a petrie dish full
of Shipley Microposit Developer Concentrate and simply immersing the
plate in this solution for about 30 seconds. You can then use the apt
to rinse and spin dry your plate by skipping through steps 1, 2, and
3 in Prog.#92.