cburian@ux4.cso.uiuc.edu (Christopher J Burian) writes:

>I just posted (finally) the latest version of the LCD FAQ containing many
>corrections and improvements.  One of the things I just now noticed that
>hasn't been corrected is this, from sec 2.5:

>]20x2 module
>]     Line 1 addresses are 00h to 13h
>]     Line 2 addresses are C0h to D3h

>Since the display data ram only goes from 00 to 7F, this is kind of
>impossible.  Does anyone know where line 2 really starts on the 20x2?
>40h, like the others?  (This was copied straight off of the Optrex 
>datasheet.)  

Yes, 40h; it's determined by the HD44780 controller alone, so it will be the
same for any module using that controller.